282 Keysight N5990A MIPI M-PHY Receiver Test User Guide8 Sys Burst Testsis measured using a real time oscilloscope. Among all measuredTTERM-OFF-SYS-RX values, the maximum and minimum TTERM-OFF-SYS-RXvalues are considered as the final results.The test will pass if the maximum T TERM-OFF-SYS-RX value measured is lessthan the time defined by the DUT's Sleep Time capability attribute.This test is performed at each selected lane and PWM gear and it is testedat the minimum and maximum data rate value for all gears.Connection DiagramRefer to the connection diagrams shown in the Connection Diagramsection of the Test 2.1.4-HS-RX Differential Termination Enable Time test.ParametersThe parameters used in Expert Mode for this test, are as follows:• CDR Loop Bandwidth (if CDR is selected in the Special Parameterdialog, see “BERT Analyzer Settings”)• CDR Peaking (if CDR is selected in the Special Parameter dialog, see“BERT Analyzer Settings”)• CDR Transition Density (if CDR is selected in the Special Parameterdialog, see “BERT Analyzer Settings”)• CDR Loop Order (if CDR is selected in the Special Parameter dialog,see “BERT Analyzer Settings”)• Set Single Ended Amplitude• Set Offset• Prepare Length• Sleep Length• Sleep Time Capability• Test Sequence• IBerReader Init Mode• Lane Under Test Termination ModelThese parameters are listed in alphabetical order in Table 6.DependenciesThe calibrations required for this test are as follows:• Reference Clock Calibration• Level Calibration Terminated / Into Open