40 Keysight N5990A MIPI M-PHY Receiver Test User Guide2 N5990A M-PHY StationDUT ParametersThe DUT Parameters are listed below in Table 1.Table 1 DUT Parameter ListParameter Name Parameter DescriptionProductProduct Number The selected name will be used to identify the product when the “Database Offline” option is selected.Serial Number The selected serial number will be used to identify the product when database option is selected.Product Type The product type can be selected as:• Receiver• TransmitterIf Receiver is selected, the main window will display the set of tests corresponding to receiver testing:HS-RX, PWM-RX, SYS-RX and SQ-RX tests.If Transmitter is selected, the main window will display the set of tests corresponding to the transmittertesting:HS-TX, PWM-TX and SYS-TX tests.Test Type By default, the test type is set to Phy Test: physical layer test.Description A description of the DUT ca be added.Num of Channels Here, you can select the number of DUT input channels (Receiver tests) or output channels (Transmittertests) to be tested.• M8020A allows to test up to 4 channels.• N4903B allows to test up to 2 channels. When used together with the Bitifeye 2100 Switch, up to 4channels can be tested.Protocol It can be selected as follows:• DigRFv4• LLI (Low Latency Interface)• UniPro (Unified Protocol)• SSIC (Super Speed Inter Chip)• PCIe (PCI Express)• UFS (Universal Flash StorageTestUser Name A user name can be added to the test information.Comment A comment can be added to the test information.Initial Start Date Time stamp of the start of the current test session.Last Test Date Time stamp of the last test conducted in the current session.Compliance Mode In this mode, the tests are conducted as mandated by the CTS, the test parameters used in the calibrationand test procedures are shown but cannot be modified by the user.