General Description 2-9STATUS LampThe STATUS lamp stays lit in green when the CPU blade is in successful operation. When theSTATUS lamp is flashing in amber or red, it indicates that the system has failed.In addition, you can view the detailed information on error message on virtual LCD when theSTATUS lamp is flashing in amber or red.You can use the virtual LCD through the Web browser of EXPRESSSCOPE engine (BMC) or NECESMPRO Manager.The following table lists indications of the STATUS lamp, descriptions, and actions to take.If an error occurs, contact your service representative.NOTE: If the CPU blade has the NEC ESMPRO installed, you canview the System Event Log (SEL) to identify the cause of a trouble.STATUS lamp indicationsSTATUS lampStatus Color Description ActionOn Green The CPU blade is operatingnormally.–Off – The power is turned off. Turn on the power.On Red BMC is being initialized. 1. Wait until the lamp goes off.2. If the lamp still goes on, checkinstallation of the CPU blade.Flash Red See the table "Virtual LCD indications when STATUS lamp is flashing inred" described later.Flash Amber See the table "Virtual LCD indications when STATUS lamp is flashing inamber" described later.NOTE: If the CPU blade is powered off while the STATUS lamp isflashing in amber or red, the indication of the STATUS lamp is retainedexcept for certain factors. When the CPU blade is powered on, theSTATUS lamp goes on green (normal status).