en-938821/2 7 - 7System Faults77.5 Sampling Period Too SmallMessage displayed at initialisationSAMPLING PERIOD TOO SMALL !IT MUST BE, AT LEAST, EQUAL TOXXXX MICROSECONDSFOR THE NUMBER OF AXIS/SPINDLESSPECIFIED IN MACHINE SETUP DATADO YOU WANT TO CONTINUE ? (Y/N)CommentThe sampling period set by parameter P50 (See Parameter manual) is too short to deal with the number of axes andspindles to be measured.ActionsCheck the minimum sampling period (T) recommended by the message.Acknowledge the message. + YThe system is available, but the axes and spindles are ignored.The system fault indicator «CLKOV» is displayed in the status window (See 3.1.3).Enter the sampling period value (T) in parameter P50 (See Parameter manual).Reset the system to take the new value into account.If the problem persists:Progressively increase the value of parameter P50 until operation is correct.REMARK Setting a P50 parameter value higher than necessary reduces the systemperformance; it is therefore advised not to increase this value too much.