7 - 16 en-938821/27.20 QVN Axes MissingMessage displayed at initialisationERROR: MISSING QVN DECLARED AXESCONTINUE (Y/N)?CommentSpeed sensor addresses declared in parameter P71 are not included in the list of servo-controlled axes declared inparameter P3 (See Parameter Manual).ActionsAcknowledge the message. + YThe system is available, but the machining modes are inhibited and power cannot be applied to the system.The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).Enter the missing axis addresses in parameter P3 (See Parameter Manual).Reset the system to take the new parameter into account.7.21 Missing QVN Measured-Only AxesMessage displayed at initialisationERROR: MISSING QVN DECLARED MEASURINGONLY AXESCONTINUE (Y/N)?CommentThe addresses of axes declared as measured only by QVN (sensor declared in P70 but not in P71) are not includedin the list of measured-only axes (declared in P2 but not in P3, see Parameter Manual).ActionsAcknowledge the message. + YThe system is available, but the machining modes are inhibited and power cannot be applied to the system.The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).Enter the missing axis addresses in parameter P2 (See Parameter Manual).Reset the system to take the new parameter into account.