7 - 12 en-938821/27.12 Incoherent QVN Sensor AddressMessage displayed at initialisationERROR: QUESTIONABLE SENSOR NUMBERCONTINUE (Y/N)?CommentA position or speed sensor address is outside the value authorised for parameters P70 and P71 (See ParameterManual).ActionsAcknowledge the message. + YThe system is available, but the machining modes are inhibited and power cannot be applied to the system.The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).Correct the faulty address in parameter P70 or P71 (See Parameter Manual).Reset the system to take the new parameter into account.7.13 Sensor Declared on QVN Card but Detected on an Axis CardMessage displayed at initialisationERROR: SENSOR DECLARED ON QVN CARD BUTDETECTED ON AN AXIS CARDCONTINUE (Y/N)?CommentA sensor is declared as connected in parameter P70 (See Parameter Manual) but is detected on an axis card.ActionsAcknowledge the message. + YThe system is available, but the machining modes are inhibited and power cannot be applied to the system.The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).Cancel the sensor declaration in parameter P70 (See Parameter Manual).Reset the system to take the new parameter into account.