3-233.1.8 EEPROM InitializationThe treatment for EEPROM Initialization at each phenomenon is displayedas Diagram 3-1.Diagram 3-1 EEPROM Initial Setting RangeNo PhenomenonCU EEPROM Area PU EEPROM AreaFactoryDefaultAreaUserMenuAreaOPMenuAreaAdministratorMenu/SystemMaintenanceMenu Area (*3)F/WRevisionAreaEngine Maintenance Menu AreaBrandsAreaDrumCounterPageCounterTonerDotCounter1 User Maintenance MenuMENU RESET Operation − − − − − − − − −2 F/W Revision check errorat the time of a power on. − − (*4) − − − − −3 CU EEPROM area mappingRevision check error at thetime of a power on.(*4) − − − − − −4 Brands area check error atthe time of a power on. (*1) (*4) − − − −5 Engine Maintenance MenuENGINE RESET Operation − − − − − − − (*2) (*5)6 PU EEPROM areamapping check error at thetime of a power on.− − − − − − (*3)7 FAC MAINTE MENUEEPROM RESET Operation − (*4) − − − − − −(*1) Destination Check is for the operation on the different product (destination) with the previously operatedproduct (destination). It is the reset relying on the recognition regarding the destination change by PJLcommand and the operation at POWER ON of the new product EEPROM as an error.(*2) It is reset to 0 limited by Page Count less than 500 pieces. (ENGINE RESET due to PJL Command isnot in this limitation.)(*3) About DOT SHIFT setting menu, even it is also exist in System Maintenance Menu, but becausethe setting value keeping area is allocated in PU EEPROM AREA, in the case of the item of SystemMaintenance Menu initialized, DOT SHIFT setting is not initialized. By contraries, in the case of PUEEPROM AREA initialized, DOT SHIFT setting is initialized.(*4) DOT SHIFT setting should not be initialized.(*5) Because of the support of Toner TAG, Toner Dot Counter is not reset.3.1.7 Energy conservation mode settingThis printer is equipped with two types of energy conservation mode, MODE1as "NORMAL MODE" and MODE2 as "ECO MODE."When energy conservation mode is set to "ECO MODE," the printer prints at alow speed at the beginning of cold start to reduce the period of time requiredfor warming up from the normal temperature.At factory default, it is "ECO MODE" MODE2.1. Setting method(1) Switch on the power of printer.(2) After "ON LINE" appears, open the Stacker Cover.(3) Press [ON LINE] switch for 5 second.Open the Top Cover by ONLINE and NODATA status, press [ON LINE]switch for 5 second. The following setting information displays on LCD for2 second. Then it returns to the original display automatically. The checkLED blinks.• In case of setting converted by MODE1 "NORMAL MODE" status, itchanges to MODE2 "ECO MODE".ENGINE CONTROLMODE2 *• In case of setting converted by MODE2 "ECO MODE" status, itchanges to MODE1 "NORMAL MODE".ENGINE CONTROLMODE1 *3. ADJUSTMENT