Warning Risk of Electric ShockThere is a risk of electric shock during replacement of the low voltage power supply.Use insulating gloves or avoid direct contact with any conducting part of the powersupply, and caution should be exercised during replacement.The capacitor may take one minute to complete discharge after the AC cord isunplugged. Also, there is a possibility that the capacitor doesn’t discharge becauseof a breakage of the PCB, etc., so remember the possibility of electric shock toavoid electric shock.4.2.7 Power Supply Unit(1) Remove the Cover-Side-R. (Refer to 4.2.4)(2) Disconnect all of the three cables from Power Supply Unit (Board) ② .(3) Remove the four screws (Silver) ① . Remove the Power Supply Unit(Board) ② .(4) Remove the Sheet-Insulation-LV ③ .(5) Remove the screw ④ .(6) Remove the two screws (Silver:8mm) ⑤ and the screw(M4) ⑥ , andremove Power Supply Unit (AC-Inlet) ⑦ .(7) Assembling is performed by the inverse procedure with removing.(Note on removing / assembling)1. Beware of not to touch the DC motor inattentively (Do not rotate motor).2. Do not apply excessive pressure to the power switch.4-104. REPLACEMENT OF PARTS