4.3.18 Guide Eject Lower Assy(1) Remove the Cover-Side-R and Cover–Side-L. (Refer to 4.2.4 / 4.2.5)(2) Remove the CU-Board. (Refer to 4.2.6)(3) Remove the Sheet-Insulation-CU. (Refer to 4.2.9)(4) Remove the Cover-Eject. (Refer to 4.2.13)(5) Remove the two screws (Silver : 8mm) ① . Remove the Cover-Cassette-Rear Assy ② and Guide-Eject-Lower-Assy ③ .(6) Remove the post ④ . Remove the Separator-SB-FD ⑤ and Spring-Separator_SB ⑥ .(7) Remove the Lever-Exit-Sensor ⑦ and Spring-Sensor-Exit ⑧ .(8) Remove the Exit-Sensor ⑨ .(9) Assembling is performed by the inverse procedure with removing.(Note on removing / assembling)1. Beware of not to touch the DC motor inattentively (Do not rotate motor).2. Install Cover-Cassette-Rear Assy ② carefully to avoid the FFC cablefrom being caught.AAFFC cable4-204. REPLACEMENT OF PARTS