45641001TH Rev.1 10-5 /Oki Data CONFIDENTIAL10.3 Notices10.3.1 Setting codeEach signal will be enabled by configuring the setting code “08-9016” (Counter installedexternally).08-90160: No external counter (Default)1: Coin controller5: Coin controller supporting ACS10.3.2 Setting value change and restrictions when using the coin controller1. Setting value- 08-9016 (Counter installed externally): Set to “1” (Coin controller). The coin controllersupporting ACS (Auto Color Selection) can be connected by setting to “5” (Coin controllersupporting ACS/ mixed-size). However, operation is not guaranteed unless the specificationfor the ACS timing is met.- 08-9017 (Setting for counter installed externally): It should be charged precisely accordingto the usage.Example: To charge only when copies are made, set to “1”.- 08-6011 (Definition setting of large sized paper):- Setting value “0”: Set this value to regard A3, LD, undefined, and custom size thatexceeds 415 mm as large size.- Setting value “1”: Set this value to regard A3, LD, undefined, B4, Folio, 14”LG, 13.5”LG,13”LG, Computer and custom size that exceeds 325 mm as large size.- Setting value “2”: Set this value to regard B4 and custom size that exceeds 325 mm aslarge size.