38 (E)ENGLISHSetup Software Displaying the “Setting” tab List boxThe IP address of the AW-RP50 connected to thenetwork is displayed here.The information of the network environment establishedby the AW-RP50 selected here is displayed on the“Setting” tab. TypeThe units connected to the selected AW-RP50 aredisplayed in this column.CAMERA: Remote cameraSW: Switcher GroupThe numbers of the groups of cameras controlled by theselected AW-RP50 are displayed in this column. CAMERA NoThe numbers of the cameras controlled by the selectedAW-RP50 are displayed in this column. TypeThe connection methods used for the units connected tothe selected AW-RP50 are displayed in this column.Serial: Serial connectionNetwork: IP connectionNoAsign: No setting (default setting)The connection method can be changed manually.Click on the right, and select “Serial,” “Network” or“NoAsign”.“Serial” can be selected only with Group 1.After the method has been changed, click the [SET] button toreflect the change. CAMERA NameThe names of the cameras set in the remote cameras aredisplayed in this column.They are displayed for the remote cameras in thecurrently selected group.For remote cameras with a serial connection, they aredisplayed only when the cameras are selected by the unit. SW InputThe input connectors of the switcher are displayed in thiscolumn.The input connector can be changed manually.Click on the right, and select “NoAsign” or an inputconnector from “INPUT1” to “INPUT5.”After the connector has been changed, click the [SET] buttonto reflect the change. MAC AddressThe MAC addresses of the remote cameras and switcherconnected to the selected AW-RP50 are displayed in thiscolumn. IP AddressThe IP addresses of the remote cameras and switcherconnected to the selected AW-RP50 are displayed in thiscolumn.The IP addresses can be changed by inputting them directly.After inputting an IP address, click the [SET] button to reflectthe change. HTTP PortThe numbers of the ports used to connect the selectedAW-RP50 are displayed in this column. CAMERA SelectThe numbers of the cameras to be changed are displayedin this column.The numbers of the cameras can be changed manually.Click on the right, and select a number from “C001” to“C100.”After the camera number has been changed, click the [SET]button to reflect the change. AlarmThe alarm information of the remote cameras is displayedin this column.They are displayed for the remote cameras in thecurrently selected group.For remote cameras with a serial connection, they aredisplayed only when the cameras are selected.