A200/A100 HardwareInstallation and Wiring2 − 42.2 Installation Environment and Mounting Space2.2 Installation Environment and Mounting SpaceAvoid Installing the Equipment in Locations with the Following Characteristics− Where the temperature is outside the range of 0°C to 50°C.− Where the relative humidity is outside the range of 35%RH to 75%RH.− Where there is a danger of condensation due to sudden temperature fluctuations.− In the presence of corrosive gas or combustible gas.− Where dust, metal powders, or salt are present in large amounts.− In an environment where there is a possibility that organic solvents such as benzene,paint thinner, or alcohol, or strong alkaline substances such as ammonia or causticsoda may adhere.− Where the equipment will be subject to vibration or shock.− In direct sunlight.− Where there is a possibility that water, oil, or chemicals may come into direct contact.− Where there will be a weight load placed on the main unit.Noise Considerations− Install the unit as far away as possible from high−voltage lines and equipment, drivelines and equipment, and other equipment that may generate large power surgeswhen it turns on or off.− Install the unit as far away as possible from equipment such as amateur radiotransmitters.