A200/A100 HardwareInput/Output Terminals (Input/Output Ports)3 − 103.6 Electric Power Wiring3.6 Electric Power WiringTerminal Positions24 V DC electric power is supplied by attach-ing wires to the input terminal block’s (+) and(–) terminals and to the ground terminal (frameground).Twist the electric wires in order to reduce theeffects of noise.24 V DCFUNCTIONALEARTHRated voltage 24 V DCAllowable voltage range 21.6 V to 26.4 V DCRated current consumption 1 camera = 0.7A2 cameras = 0.9AUse a Power Supply with an Isolating Internal Protection Circuit− Use an isolating power supply that incorporates an internal protection circuit in orderto protect against abnormal voltages coming from the electric lines.− The controller regulator is non−isolated.− When using an electrical device that does not have an internal protective circuit besure to supply electric power to the controller only after passing it through a fuse orother protective element.Switch the power on and off at the primary side.− Switch the power on and off at the primary side (100 V AC). If you switch the poweron and off at he secondary side (24 V DC), you can cause the fuses to blow.PowersupplyPrimarysideSecondaryside100 VAC–+24 V DCMicroImage-CheckerPrimary side Secondary side100 VAC +24 V DCMicroImage-CheckerIncorrect CorrectPowersupplyUse a power supply that has sufficient surplus capacity!− When you first switch the power on, the temporary in−rush current far exceeds therated current. Therefore, be certain to use a power supply that has sufficient surpluscapacity to handle this (i.e. rated at about three times the steady−state current), andtest it to ensure that it operates correctly.