Chapter 4 Settings — [PICTURE] menuENGLISH - 67Notef When a name is changed, display of [USER] is also changed.[GAMMA]You can adjust contrast balance.1) Press as to select [GAMMA].2) Press qw or the button.f The [GAMMA] individual adjustment screen is displayed.3) Press qw to adjust the level.Operation Adjustment Range of adjustmentPress w. The midtones become brighter. -8 - +7Press q. The midtones become darker.[SHARPNESS]You can adjust the sharpness of the projected image.1) Press as to select [SHARPNESS].2) Press qw or the button.f The [SHARPNESS] individual adjustment screen is displayed.3) Press qw to adjust the level.Operation Adjustment Range of adjustmentPress the w button. Contours become sharper. 0 - +15Press the q button. Contours become softer.Notef If you press w while the adjustment value is [+15], the value will become [0]. If you press q while the adjustment value is [0], the value willbecome [+15].[NOISE REDUCTION]You can reduce noises when the input image is degraded and noise is occurring in the image signal.1) Press as to select [NOISE REDUCTION].2) Press qw or the button.f The [NOISE REDUCTION] individual adjustment screen is displayed.3) Press qw to switch the item.f The items will switch each time you press the button.[OFF] No correction.[1] Slightly corrects the noise.[2] Moderately corrects the noise.[3] Strongly corrects the noise.Attentionf When this is set for an input signal with less noise, the image may look different from what it originally was. In such a case, set it to [OFF].[IRIS]Aperture correction is performed automatically based on the image to result in an image of optimum contrast.1) Press as to select [IRIS].2) Press qw or the button.f The [IRIS] individual adjustment screen is displayed.