Control commands via LANWhen WEB Control administrator rights password is set (Protect mode)Connection methodObtain the IP address and port number (Initial set value = 1 024) of the projector and make a request1)for connection to the projector.Acquire the IP address from the menu screen of the projector, and the port number from the WEB control page.fIP address : Obtain from MAIN MENU → [NETWORK] → [STATUS]Port No. : Acquire from the WEB control [Detailed set up] → [Port set up] pageThere is a response from the projector.2)Data section Blank Mode Blank Random number section Termination symbolCommandexample“NTCONTROL”(ASCII string)‘ ’0x20‘1’0x31‘ ’0x20“zzzzzzzz”(ASCII code hexadecimalnumber)(CR)0x0dDatalength 9 bytes 1 byte 1 byte 1 byte 8 bytes 1 byteMode : 1 = Protect modefGenerate a 32-byte hash value from the following data using MD5 algorithm.3)“xxxxxx:yyyyy:zzzzzzzz”fxxxxxx : Administrator rights user name for WEB CONTROL (Default user name is “admin1”)yyyyy : Password of above administrator rights user (Default password is “panasonic”)zzzzzzzz : 8-byte random number obtained in Step 2Command transmission methodTransmit using the following command format.Transmitted datarHeader Data section Termination symbolCommandexampleHash value(See above)‘0’0x30‘0’0x30Control command(ASCII string)(CR)0x0dData length 32 bytes 1 byte 1 byte Undefined length 1 byteReceive datarHeader Data section Termination symbolCommandexample‘0’0x30‘0’0x30Control command(ASCII string)(CR)0x0dData length 1 byte 1 byte Undefined length 1 byteError responserString Details Termination symbolMessage"ERR1" Undefined control command(CR)0x0d"ERR2" Out of parameter range"ERR3" Busy state or no-acceptable period"ERR4" Timeout or no-acceptable period"ERR5" Wrong data length"ERRA" Password mismatchData length 4 bytes ― 1 bytes102 - ENGLISHChapter 6 Appendix - Technical Information