8. Troubleshooting8-26 September 2002 9128-A2-GB20-80Physical TestsPhysical tests require the participation of your network service provider.Main Menu →Test→[Network Physical Tests/Data Port Physical Tests/DSX-1 Physical Tests/PRI Physical Tests]If the unit does not have the ISDN PRI DBM feature, PRI Physical Tests does notappear.A FrameSaver unit’s physical tests screen for the network interface is shownbelow.Physical Tests Screen ExampleThe InjectErr function key at the bottom of the screen only appears when a SendPattern Test is Active. Select InjectErr to inject a single bit error into the patternbeing sent.The ResetMon function key at the bottom of the screen only appears when aMonitor 511 test pattern is Active. Select ResetMon to reset the monitor patternerror counter.CAUTION:You should not run these tests with frame relay equipment attached;you must disconnect the frame relay equipment and use external testequipment.main/test/network 9128-IIDevice Name: Node A 5/26/2000 23:32NETWORK 1 PHYSICAL TESTSTest Command Status ResultsLocal LoopbacksLine Loopback: Start Inactive 0:00:00Payload Loopback: Start Inactive 0:00:00Repeater Loopback: Start Inactive 0:00:00Remote LoopbacksSend Line Loopback: Down Send Inactive 0:00:00Pattern TestsSend: user-defined 0a0a Stop Active 0:00:00 - Errors 99999+Monitor: user-defined0a0a Stop Active 0:00:00 - Errors 99999+--------------------------------------------------------------------------------Ctrl-a to access these functions, ESC for previous menu MainMenu ExitInjectErr ResetMon