F. Technical SpecificationsF-6 September 2002 9128-A2-GB20-80Physical EnvironmentOperating temperatureStorage temperatureRelative humidityShock and vibration35°F to 122°F (1.7°C to 50°C)–4°F to 158°F (–20°C to 70°C)5% to 85% (noncondensing)Withstands normal shipping and handlingPhysical DimensionsHeightWidthDepth10.5 inches (26.7 cm) or 6U17.2 inches (43.7 cm)14.3 inches (36.3 cm)Weight Empty access carrier (without power supply)11 lbs. 6 oz. (5.16 kg)AC Power RequirementsAC Power SupplyDC Power Supply90 to 265 VAC, 50/60 Hz ±3A maximum–48 VDC, 6.6 amps, 316 wattsHeat Dissipation (Max.)227 VAC–48 VDCFully loaded access carrier585 Btu per hour maximum465 Btu per hour maximumTypical Power ConsumptionAC Power Supply1 power supply installed2 power supplies installedDC Power Supply1 power supply installed2 power supplies installed100 VAC 60 Hz 1.7 amps 171 watts120 VAC 60 Hz 1.03 amps 60 watts100 VAC 50 Hz 1.15 amps 60 wattsResult: 207 Btu per hour100 VAC 60 Hz 1.25 amps 64.5 watts120 VAC 60 Hz 1.5 amps 177 watts230 VAC 50 Hz 0.9 amps 172 wattsResult: 221 Btu per hour104 watts at –48 VDCResult: 355 Btu per hour124 watts at –48 VDCResult: 423 Btu per hourTable F-3. 14-Slot 9000 Series Access Carrier Technical Specifications (2 of 2)Specification Criteria