4. Configuration Options9128-A2-GB20-80 September 2002 4-53Time Slot Assignment Rule:Valid network time slots are either Available or contain a Frame Relay Link 1assignment.Procedure1. Follow this menu selection sequence:Main Menu →Configuration →Time Slot Assignment →Frame Relay Network AssignmentsThe Frame Relay Network Assignments screen appears. This screen containsa matrix of the current assignment status of all time slots on the networkinterface.2. Enable or disable Time Slot Discovery.— When enabled, the unit examines all time slots not cross-connected toother ports to determine which time slots are being used by the networkfor frame relay traffic. These time slots are set to FrameRly1. This is thefactory default.— When disabled, time slot assignments must be manually configured.3. If Time Slot Discovery is disabled, assign network time slots for use by framerelay service, link 1, by typing FrameRly1 in the selected Network field.4. Repeat Step 3 until all desired time slots are assigned.5. Save the configuration.Assigning DSX-1 Time Slots to the Network InterfaceDSX-1 time slots are assigned by channel allocation, where you specify individualtime slots. The DSX-1 interface must be enabled to assign DSX-1 time slots to thenetwork interface (see Table 4-8, DSX-1 Physical Interface Options).Value MeaningNtt It represents time slottt of the selected network interface.Assigned The time slot is already assigned to something other than a DSX-1time slot, so it is unavailable. Assigned time slots cannot be modifiedfrom this screen.Available The time slot is currently unassigned.DSX-1/tt Slottt of the DSX-1 interface is assigned to the network interfacetime slot identified right above it (Ntt).