Parker EME Compax3 AccessoriesI11 T11 192-120101 N6 - March 2004 1278.6 External ballast resistorsIn this chapter you can read about:Ballast resistor BRM8/01 ..............................................................................................................128Ballast resistor BRM5/01 ..............................................................................................................128Ballast resistor BRM6/02 ..............................................................................................................128Ballast resistor BRM4/0x...............................................................................................................129Danger! Hazards when handling ballast resistors!Housing temperature up to 200∞C!Dangerous voltage!The device may be operated only in the mounted state!The external ballast resistors must be installed such that contact withthe human body is prevented.Install the connecting leads at the bottom.Observe the instructions on the resistors (warning plate).The ballast resistors are equipped with a 1.5m connecting lead.Please note that the length must not exceed 2mBallast resistors for Compax3Ballast resistor Device sustained dynamicBRM8/01 (100ΩΩΩΩ) Compax3 S025 V2Compax3 S038 V460W 250W (<1s; ≥10s cooling time)BRM5/01 (56ΩΩΩΩ) Compax3 S063 V2Compax3 S075 V4180W 2300W (<0.4s; ≥8s coolingtime)BRM6/02 (33ΩΩΩΩ) Compax3 S150 V4 570W 6900 W (<1s; ≥ 20s coolingtime)BRM4/01 (15ΩΩΩΩ) Compax3 S300 V4 570W 6900 W (<1s; ≥ 20s coolingtime)BRM4/02 (15ΩΩΩΩ) Compax3 S300 V4 740W 8900W (<1s; ≥20s cooling time)BRM4/03 (15ΩΩΩΩ) Compax3 S300 V4 1500W 18kW (<1s; ≥20s cooling time)