Parker EME ConfigurationBallast resistorI11 T11 192-120101 N6 - March 2004 39Compax3 S0xx V2 at 230VAVPower outputstage switchingfrequencyS025 V2 S063 V2I nominal 2.5Aeff 6.3Aeff8kHzpre-set I peak (<5s) 5.5Aeff 12.6AeffI nominal 2.5Aeff 5.5Aeff16kHzI peak (<2,5s) 5.5Aeff 12.6AeffCompax3 S0xx V4 at 3*400VACPower outputstage switchingfrequencyS038 V4 S075 V4 S150 V4 S300 V4I nominal - - 15Aeff 30Aeff4kHzI peak (<5s) - - 30Aeff 60AeffI nominal 3.8Aeff 7.5Aeff 10.0Aeff 26Aeff8kHzI peak (<2,5s) 9.0Aeff 15.0Aeff 20.0Aeff 52AeffI nominal 2.5Aeff 3.7Aeff 5.0Aeff 14Aeff16kHzI peak (<2,5s) 5.0Aeff 10.0Aeff 10.0Aeff 28AeffCompax3 S0xx V4 at 3*480VACPower outputstage switchingfrequencyS038 V4 S075 V4 S150 V4 S300 V4I nominal - - 13.9Aeff 30Aeff4kHzpre-set I peak (<5s) - - 30Aeff 60AeffI nominal 3.8Aeff 6.5Aeff 8.0Aeff 21.5Aeff8kHzI peak (<2,5s) 7.5Aeff 15.0Aeff 16.0Aeff 43AeffI nominal 2.0Aeff 2.7Aeff 3.5Aeff 10Aeff16kHzI peak (<2,5s) 4.0Aeff 8.0Aeff 7.0Aeff 20AeffThe values marked with grey re the pre-set values (standard values)!4.1.3. Ballast resistorIf the regenerative brake output exceeds the amount of energy that can bestored by the servo-controller (see on page 143), an error will be generated. Toensure safe operation, it is then necessary to either! reduce the accelerations resp. the decelerations,! or an external ballast resistor (see on page 127) is required.Please select the connected ballast resistor or enter the characteristic values ofyour ballast resistor directly.Please note that with resistance values greater than specified, the poweroutput from the servo drive can no longer be dissipated in the ballastresistor.