Introduction14 I11 T11 192-120101 N6 - March 20041.6 Conditions of utilization1.6.1. Conditions of utilization for CE-conform operation- Industry and trade -The EC guidelines for electromagnetic compatibility 89/336/EEC and for electricaloperating devices for utilization within certain voltage limits 73/23/EEC are fulfilledwhen the following boundary conditions are observed:Operation of the devices only in the condition in which they were delivered,i.e. with all housing panels.A mains filter is required in the mains input line if the motor cable exceeds a certainlength. Filtering can be provided centrally at the plant mains input or separately atthe mains input to each device.Commercial and residential area (limit values of Class A in accordance withEN 61800-3)The following mains filters are available for independent utilization:Device: Compax3 Order No.: Condition:S0xx V2: NFI01/01 Only for motor lines longer than 10mS038, S075, S150 V4: NFI01/02 Only for motor lines longer than 10mS300 NFI01/03 Only for motor lines longer than 10mIndustrial area (limit values in accordance with EN 61800-3)Longer motor cable lengths are possible in industrial areas without a mains powerfilter.Connection length: connection between mains filter and device:unscreened: < 0.5mshielded: < 5m (fully shielded on ground ñ e.g. ground of control cabinet)Operation of the devices only with Parker motor and resolver cables (theirplugs contain a special full surface area screening).The following cable lengths are permitted:< 100 m (the cable should not be rolled up!)A motor output filter is required for motor cables >20 m.! MDR01/04 (max. 6.3A rated motor current)! MDR01/01 (max. 16A rated motor current)! MDR01/02 (max. 30A rated motor current)Mains filter:Motor and resolvercable:Motor cable