Status values90 I11 T11 192-120101 N6 - March 20046.8 IEC61131-3Status of cycle time of the control program Object 50.3Available in technology function: T10, T11, T30, T40Unit ofmeasurement n/a User level standardD/A monitor output not possible D/A monitor:measurement unit of thereference value-Remark: Current cycle time [unit: 1=500 μs] of the control programStatus of maximum cycle time Object 50.4Available in technology function: T10, T11, T30, T40Unit ofmeasurement n/a User level standardD/A monitor output not possible D/A monitor:measurement unit of thereference value-Remark: Maximum cycle time [unit : 1=500 μs]Very large values may occur here with the command "Save objectspermanently". Then the control program will no longer be executed forthe execution time (about 1.5 sec)Setpoint for analog output 0 Object 634.4Available in technology function: T11, T30, T40Unit ofmeasurement n/a User level advancedD/A monitor output possible D/A monitor:measurement unit of thereference value-Remark: Setpoint for analog output 0 (DA0 - X11/4); can be used as a DAmonitor.This output must be previously activated to be able to access it. Youcan do this in the ServoManager in the optimization window in thepartial window at the bottom left under DA monitor.Convert the signal source to IEC61131.Setpoint for analog output 1 Object 635.4Available in technology function: T11, T30, T40Unit ofmeasurement n/a User level advancedD/A monitor output possible D/A monitor:measurement unit of thereference value-Remark: Setpoint for analog output 1 (DA1 - X11/3); can be used as DA monitor.This output must be previously activated to be able to access it. Youcan do this in the ServoManager in the optimization window in thepartial window at the bottom left under DA monitor.Convert the signal source to IEC61131.