G.SHDSL Port Details window 122Models 2616RC, 3096RC & 3196RC Admin Reference Guide 9 • G.SHDSL (Model 3096RC)Note The Line Provision Rate parameter label also functions as a hyperlink.Click the Line Provision Rate hyperlink to open the G.SHDSL LineProvision window (see “G.SHDSL Line Provision window” onpage 129).• Clock Mode (gshDSLClockMode)—Indicates whether the clocking for this G.SHDSL link is provided andcontrolled by the T-DAC or the remotely connected CPE device.• Payload Rate (gshDSLPayloadRate)—Defines the payload rate (i.e. data rate as opposed to line rate) forthis G.SHDSL link. The following values of Payload Rates may be defined for T-DAC G.SHDSL ports:Note If the Payload Rate has been configured for either r64(1) or r128(2),the DSL link will establish at 192 kbps. The 3096RC will then con-figure the lower payload rate using EOC, a process which may takeup to 2 minutes. The CPE will then retrain. It will properly pass dataonly after the link comes up the second time.• # of I-Bits (gshDSLIbitSel)—Defines the number of I bits transmitted in each G.SHDSL frame. The fol-lowing values may be defined:- b0(0)- b1(1)- b2(2)- b3(3)- b4(4)- b5(5)- b6(6)- b7(7)• Annex Type (gshDSLAnnexSel)—Defines the Annex type to be used on the link connected to this port.The following values may be defined:- annex-A(1)—Typically used in North America- annex-B(2)—Typically used outside North America• Transmit Power (gsDSLTxGain)—Enables you to increase or decrease the transmit power setting in 1-decibel increments.- r64(1) - r128(2) - r192(3) - r256(4) - r320(5) - r384(6)- r448(7) - r512(8) - r576(9) - r640(10) - r704(11) - r768(12)- r832(13) - r896(14) - r960(15) - r1024(16) - r1088(17) - r1152(18)- r1216(19) - r1280(20) - r1344(21) - r1408(22) - r1472(23) - r1536(24)- r1600(25) - r1664(26) - r1728(27) - r1792(28) - r1856(29) - r1920(30)- r1984(31) - r2048(32) - r2112(33) - r2176(34) - r2240(35) - r2304(36)