iDSL Port Details window 141Models 2616RC, 3096RC & 3196RC Admin Reference Guide 10 • iDSL (Model 3196RC)3. Click the Port # number link (see figure 74).Figure 74. Port # linksThe iDSL Port Details window is organized into the following groups:• Operator action buttons at the top of the page• iDSL Port Status and Statistics tables below the operator action buttonsThe following paragraphs describe the contents of the iDSL Port Details window.Figure 75. Operator action buttons section of the iDSL Port Details windowOperator action buttonsThe iDSL Port Details window provides the following operator action buttons (see figure 75):• Back—Displays the previous page. When you click the Back button the T-DAC moves you back one level tothe iDSL Port Configuration window.• Refresh Current Page—Refreshes the display. When you click the Refresh Current Page button, the T-DAC retrieves parameter values currently stored in DRAM and displays them on the page. Any config-urable parameter values entered or selected since you last clicked (submit) will be overwritten with valuesretrieved from DRAM. When monitoring operating status or statistics, or when defining new values forconfigurable parameters, use this button to update the display. You can watch any changes take The porterror counts accumulate from that point forward. Each time you click the Clear Errors button the T-DACwill clear all errors for this port, resetting the counters to zero.• Previous Port—Displays the iDSL Port Details page for the next lower numbered iDSL port. For example, ifyou are viewing the iDSL Port 3 Details page, when you click the Previous Port button the T-DAC will dis-play the iDSL Port 2 Details page. If you are viewing Port 1, page 16 will be displayed.• Next Port—Displays the iDSL Port Details page for the next higher numbered iDSL port. For example, ifyou are viewing the iDSL Port 3 Details page, when you click the Next Port button the T-DAC will displaythe iDSL Port 4 Details page. If you are viewing Port 16, page 1 will be displayed.• Clear Errors—Clears all errors on this port. Resets the port statistical error counters to zero (0). A burst oferrors typically occurs during port activation. Five (5) seconds after the port enters dataMode(1) the T-DACwill reset the statistical error counters to zero (0) in order to clear these expected startup errors. The porterror counts accumulate from that point forward. Each time you click the Clear Errors button the T-DACwill clear all errors for this port, resetting the counters to zero.