3–Fibre Channel ConfigurationConfiguring CS_CTL QoS81 BK3254601-00 CFor information about using Fibre Channel trace route in QConvergeConsoleVMware vCenter Server Plug-in or QConvergeConsole VMware vSphere WebClient Plug-in, see the section “Diagnostic Tests—Fibre Channel Port” in theUser’s Guide—QConvergeConsole Plug-ins for VMware vSphere (part numberSN0054677-00).Configuring CS_CTL QoSThis section provides the following information on class-specific control (CS_CTL)quality of service (QoS): CS_CTL QoS Features Enabling CS_CTL QoS Mode for the Initiator and Target Ports Verifying and Confirming CS_CTL Mode Setup for Each Port Creating a Virtual Port from the Adapter’s Port in QConvergeConsole GUI Setting the QoS Priority Level for a Virtual Port in QConvergeConsole GUICS_CTL QoS FeaturesThe following highlights some of the features of the CS_CTL QoS: Traffic priority classification for QLogic Gen6 Fibre Channel SAN. QoS at thepacket level is realized by using the CS_CTL field, which is specified in theFC-FS-2 specification. QoS allows one to prioritize frames between a hostand target, depending on the value of the CS_CTL field in the FC Frameheader. Extending QoS from the fabric to the host Enables QLogic Fibre Channel users to rapidly scale server virtualizationwithout compromising service-level agreements Benefits for both physical and virtual server deployments Supported configuration: QLogic 2700 Series Adapters CS_CTL-based QoS is end-to-end (requires target to supportCS_CTL)NOTEFor information about end-to-end CS_CTL QoS, see “ConfiguringEnd-to-End CS_CTL QoS” on page 84.