RADWIN Manager Community Strings Chapter 8WinLink™ 1000 User Manual Release 1.9 8-9• For Read-Write Community, usenetman.• For Read-Only Community, usepublic.• For Trap Community, usepublic¾To change a Community string:1. From the Configuration dialog box, choose the Security tab.2. Type the current read-write Community (default isnetman).3. Choose the communities to be changed by clicking the check box.4. Type the new Community string and re-type to confirm.5. Click OK to save.Figure 8-8: Changing the Community StringForgotten Community stringIf the read-write Community string is unknown, an alternative Communitykey can be used. The alternative Community key is unique per ODU and canbe used only to change the Community strings. The alternative Communitykey is supplied with the product, and should be kept in a safe place.If both the read-write Community and the alternative Community key areunavailable, then an alternative Community key can be obtained from RAD-WIN Customer Support using the ODU serial number or MAC address. Theserial number is located on the product label. The serial number and theMAC address are displayed in the Site Configuration inventory tab.When you have the alternative Community key, click the Forgot Commu-nity button and enter the Alternative Community key (Figure 8-9). Thenchange the read-write Community string.