Chapter 8: Device Management157Trap Name DescriptionuserSessionTimeout A user with an active session has experienced asession termination due to timeout.userUploadedCertificate A user uploaded a SSL certificate.vmImageConnected User attempted to mount either a device or imageon the target using Virtual Media. For everyattempt on device/image mapping (mounting) thisevent is generated.vmImageDisconnected User attempted to unmount a device or image onthe target using Virtual Media.Power Supply SetupThe KX II provides dual power supplies, and can automatically detectand provide notification regarding the status of these power supplies.Use the Power Supply Setup page to specify whether you are using oneor both of the power supplies. Proper configuration ensures that the KX IIsends the appropriate notifications should a power supply fail. Forexample, if power supply number one fails, the power LED at the front ofthe unit will turn red.To enable automatic detection for the power supplies in use:1. Choose Device Settings > Power Supply Setup. The Power SupplySetup page opens.2. If you are plugging power input into power supply number one(left-most power supply at the back of the unit), then select thePowerln1 Auto Detect option.3. If you are plugging power input into power supply number two(right-most power supply at the back of the unit), then select thePowerln2 Auto Detect option.