Chapter 8: Device Management1584. Click OK.Note: If either of these checkboxes is selected and power input is notactually connected, the power LED at the front of the unit turns red.To turn off the automatic detection: Deselect the checkbox for the appropriate power supply.To reset to factory defaults: Click the Reset To Defaults button.Note: The KX II does NOT report power supply status toCommandCenter. Dominion I (generation 1), however, does reportpower supply status to CommandCenter.Configuring PortsThe Port Configuration page displays a list of the KX II ports. Portsconnected to KVM target servers (blades and standard servers) and rackPDUs (power strips) are displayed in blue and can be edited. For portswith no CIM connected or with a blank CIM name, a default port name ofDominion-KX2_Port# is assigned, where Port# is the number of the KX IIphysical port.To access a port configuration:1. Choose Device Settings > Port Configuration. The Port ConfigurationPage opens.This page is initially displayed in port number order, but can besorted on any of the fields by clicking on the column heading. Port Number - Numbered from 1 to the total number of portsavailable for the KX II device. Port Name - The name assigned to the port. A port namedisplayed in black indicates that you cannot change the nameand that the port cannot be edited; port names displayed in bluecan be edited.Note: Do not use apostrophes for the Port (CIM) Name. Port TypePort type DescriptionDCIM Dominion CIMNot Available No CIM connectedPCIM Paragon CIM