36 RAYDATA Installation and Operation Handbook5.2 Setting AlarmsAlarms can be set for the following data:• Depth: Shallow and Deep, reported as two separate alarms• Anchor: Lower and Upper limits• Temperature: Lower and Upper limitsWhen you first install your RayData, the alarms are set as follows:Alarm Limit Value On/OffDepth Shallow 10 feet ONDepth Deep 100 feet OFFAnchor Lower 30 feet OFFUpper 60 feet OFFTemperature Lower 32 °F OFFUpper 90 °F OFFAll the display pages that deal with setting alarms are part of the DepthChapter, and are accessed as shown in the diagram below.SEATEMPSPEEDDEPTHTEMPMAINDEPTHDEPTHDEPTHSHALLOWALARMADJUSTDEPTHDEEPALARMADJUSTANCHORALARMADJUSTPAGESTEMPALARMADJUSTMINIMUMDEPTHSHALLOWALARMDEEPALARMANCHORALARMTEMPALARMReset minimum+ + + ++Press DEPTH key to return to main pageD3066-1DEPTHThe units for the alarm limits are the same as those set for the depthand temperature using the Setup pages (see Chapter 4).Note: On SeaTalk systems, these alarms are global. Any unit on thesystem, including the RayData, can set or change the alarm values,and switch the alarms on or off. The new settings are shown on all theother units.