78 ST7001+ Autopilot Control Unit - Owner’s Handbook7 Adjusting Autopilot SettingsAccessing the Calibration modeYou can only access Calibration mode from Standby mode:1. With the autopilot in Standby mode, press and hold the standbykey for 2 seconds. The display will change to show DISPLAY CAL.2. Press the disp key or down arrow key to scroll down through the4 calibration groupings:• Display Calibration (DISPLAY CAL)• User Calibration (USER CAL)• Seatrial Calibration (SEATRIAL CAL)• Dealer Calibration (DEALER CAL)Note: You can go backwards through the groups by pressing andholding the disp key for one second or by using the up arrow key.3. When you reach the Calibration group you want to access, pressthe auto key to enter that group:To prevent accidental access, we have made entry to DealerCalibration more difficult than the other groups. After pressingthe auto key, the display will show CAL. When you see this, pressthe -1 and +1 keys together to enter Dealer Calibration.4. When you have entered one of the Calibration groupings, pressdisp key or down arrow key to scroll down through the itemswithin that grouping:Note: You can go backwards through the list by pressing and holdingthe disp key for one second or by using the up arrow key.5. When you reach an item you wish to adjust, use the -1, +1, -10 and+10 keys (as appropriate) to change the value.6. If you then want to adjust settings in another Calibration group,press the standby key and then repeat steps 2 to 5 as necessary.7. When you have made all the changes you want to make, press andhold the standby key for two seconds to exit Calibration modeand save changes.