PLC-XF1000 Expand Serial Command Functional Specifications18/728. Functional Execution Command8.1 Format1) PC issues a command in the format below:Pattern1: “CF_Command” [CR]Pattern2: “CF_Command_” %1 [CR]CF_: HeaderCommand: String%1: Parameter (String)_: Space (To separate Command and Parameter)2) The projector decodes the received command and when it gets ready to receive anothercommand, it returns the response.“000” [CR]: (0x06, 0x0D) When receiving Functional Execution Command“nnn” [CR]: Except “000”, when it cannot execute commands for any specific reason.For detail, refer to [7. Error Code Table]“?” [CR]: When the received data cannot be decoded8.2 Transfer ExampleWhen setting projector’s total dots to 1344 by Expand Command.PC → PJ: “CF_TDOTS_1344” [CR]PC ← PJ: “000” [CR] ---------------- Acceptable8.3 Operation RequirementsWhen the projector status is in the status below, Functional Execution Commands are limited(Status Read Commands are available in following status)Projector Status Available Functional Execution CommandIn Standby Mode C00: POWER ONCount Down in process C00: POWER ON (Countdown is terminated)Cooling Down in process NONE (No Execution)Cooling Down in process due toabnormal temperature NONE (No Execution)In Abnormal Temperature NONE (No Execution)Power Failure(60 seconds after Power failed) NONE (No Execution)Power Saving Cooling Down in process NONE (No Execution)In Power Saving status C00: POWER ONC01: POWER OFFNote) An appropriate error code is returned when the projector receives other command in theabove status.