PLC-XF1000 Expand Serial Command Functional Specifications47/729.4.17 CR_IMAGE CommandCommand “CR_IMAGE” [CR]DetailsGet image setting status.The Required data “CUSTOM1” – “CUSTOM10” corresponds to “Image1” –“Image10” displayed when selecting Image on OSD Menu.Acceptable “000_%1” [CR]%1“STAND” ---------------------------------- Standard“REAL” ----------------------------------- Real“CINEMA” --------------------------------- Cinema“CUSTOM1” ------------------------------- “Image1”“CUSTOM2” ------------------------------- “Image2”“CUSTOM3” ------------------------------- “Image3”“CUSTOM4” ------------------------------- “Image4”“CUSTOM5” ------------------------------- “Image5”“CUSTOM6” ------------------------------- “Image6”“CUSTOM7” ------------------------------- “Image7”“CUSTOM8” ------------------------------- “Image8”“CUSTOM9” ------------------------------- “Image9”“CUSTOM10” ----------------------------- “Image10”ResponseUnacceptable“Error Code” [CR] -------------- When command is invalid in thegiven condition (such as being selected input)“?” [CR] --------- When unknown command is received9.4.18 CR_IMGGMD CommandCommand “CR_IMGGMD” [CR]Details Get setting status of Standard/Real/Cinema in Image GammaAcceptable “000_%1” [CR]%1“STD” ------------------------------ Standard“REL” ------------------------------ Real“CNM” ----------------------------- CinemaResponseUnacceptable “?” [CR]9.4.19 CR_ADVCOL CommandCommand “CR_ADVCOL” [CR]Details Get setting status of Advanced colorAcceptable “000_%1” [CR]%1 “AUTO” ------------------ Operate Advanced color with Auto“OFF” --------------- Set Advanced color OFFResponseUnacceptable “?” [CR]