PLC-XF1000 Expand Serial Command Functional Specifications63/729.10.10 CR_P-MANETIME CommandCommand “CR_P-MAETIME” [CR]Details Get setting time for starting Power Management functionAcceptable “000_%1” [CR]%1 “001 – 030” ----------------------- 1 to 30 minutesResponseUnacceptable “?” [CR]9.10.11 CR_FANSPEED CommandCommand “CR_FANSPEED” [CR]Details Get currently selected Fan Control SpeedAcceptable “000_%1” [CR]%1 “MAX” -------------------- Max speed of Fan Control is selected“NOR” -------------------- Normal speed of Fan Control is selectedResponseUnacceptable “?” [CR]9.10.12 CR_KEYDIS CommandCommand “CR_KEYDIS” [CR]Details Get setting status of RC/KEY use limitation (valid or invalid)Acceptable “000_%1” [CR]%1“NONE” ------------------------- RC & KEY are valid“RC” ----------------------------- RC is invalid“KEY” --------------------------- KEY is invalidResponseUnacceptable “?” [CR]9.10.13 CR_SHUTRCPROT CommandCommand “CR_SHUTRCPROT” [CR]Details Get status if Shutter can be controlled by R/CAcceptable “000_%1” [CR]%1 “ON” -------------------- Shutter is not controllable by R/C“OFF” ------------------- Shutter is controllable by R/CResponseUnacceptable “?” [CR]9.10.14 CR_SHUTKEYPROT CommandCommand “CR_SHUTKEYPROT” [CR]Details Get status if Shutter can be controlled by key on the top panelAcceptable “000_%1” [CR]%1 “ON” ------------- Shutter is not controllable by key on the top panel“OFF” ------------ Shutter is controllable by key on the top panelResponseUnacceptable “?” [CR]