PLC-XF1000 Expand Serial Command Functional Specifications64/729.10.15 CR_SHUTH CommandCommand “CR_SHUTH” [CR]Details Get time setting to start the shutter managementAcceptable “000_%1” [CR]%1“005” -------------------- 5 minutes“006” -------------------- 6 minutes:“179” -------------------- 179 minutes“180” -------------------- 180 minutesResponseUnacceptable “?” [CR]9.10.16 CR_SECURITY CommandCommand “CR_ SECURITY” [CR]Details Get ON/OFF setting status of Security on menu.Acceptable “000_%1” [CR]%1 “ON” ------------ PJ is locked“OFF” ----------- PJ is not locked.ResponseUnacceptable “Error Code” [CR]9.10.17 CR_PJLOCKNOW CommandCommand “CR_PJLOCKNOW” [CR]Details Get actual setting status of PIN code lockAcceptable “000_%1” [CR]%1“LOCK” ------ PJ is lockedPIN code lock is set to ON1/ON2 on the menu and PJ PIN code isnot entered, therefore PJ is actually locked.“FREE” ------- PJ is unlocked (either A or B)A) PJ lock is set to OFF on the menuB) PJ lock is set to ON1/ON2 on the menu, but PIN code Lockmode is canceled because PJ PIN code is entered.ResponseUnacceptable “Error Code” [CR]9.10.18 CR_PJLOCMENU CommandCommand “CR_PJLOCKMENU” [CR]Details Get ON/OFF setting status of PIN code lock on menuAcceptable “000_%1” [CR]%1“ON1” -------------------- PIN code lock ON 1 is set on the menu“ON2” -------------------- PIN code lock ON 2 is set on the menu“OFF” -------------------- PIN code lock OFF is set on the menuResponseUnacceptable “Error Code” [CR]9.10.19 CR_FILH CommandCommand “CR_FILH” [CR]Details Get Filter used timeAcceptable “000_%1” [CR]%1 “00000 - 99999”ResponseUnacceptable “Error Code” [CR]