PLC-XF1000 Expand Serial Command Functional Specifications59/729.9 Lamp Status Read Commands9.9.1 CR_LAMPREPL CommandCommand “CR_LAMPREPL” [CR]Details Get the information of Lamp Replacement timeAcceptable “000_%1” [CR]%1“2**”2 ---------------- indicates 2 lamps are used in this model.* ---------------- indicates the status of each lamp in lamp numberorder.“Y” means the lamp operating time is over thethreshold for lamp replacement, and “N” meansit has not reached to.e.g.“2YN” ------------ This indicates it is 2-lamp system, and Lamp #2has not been reached to the replacement timewhile #1 should be replaced.ResponseUnacceptable “?” [CR]9.9.2 CR_LAMPMODE CommandCommand “CR_LAMPMODE” [CR]Details Get Lamp mode setting statusAcceptable “000_%1” [CR]%1 “FULL” ---------------- Lamp mode is set to 2-lamp (FULL)“HALF” ---------------- Lamp mode is set to 1-lamp (HALF)ResponseUnacceptable “?” [CR]9.9.3 CR_AUTOLAMPCONTRL CommandCommand “CR_AUTOLAMPCONTRL” [CR]Details Get selected Lamp control modeAcceptable “000_%1” [CR]%1“NORMAL” ---------- NORMAL is selected.“ECO” ---------------- ECO is selected.“AUTO” -------------- AUTO is selected.ResponseUnacceptable “Error Code” [CR]9.9.4 CR_LAMPSTS CommandCommand “CR_LAMPSTS” [CR]Details Get the information of Lamp lighting statusAcceptable “000_%1” [CR]%1“2**”The first character indicates 2 lamps are used in this model.The following characters indicate each lamp status in lampnumber order as showed below.“I” ------------------------ Lamp is ON“O” ---------------------- Lamp is OFF“X” ----------------------- Lamp Failuree.g.“2IO” ------------------- This indicates it is 2-lamps system, Lamp#1 is ON, and #2 is OFF.ResponseUnacceptable “?” [CR]