DM-3200 Release Notes18 TASCAM DM-3200 Release NotesVersion 1.30Version 1.50ª Version 1.50 Remote controlPreviously, the LCD would unexpectedly switch focuswhen both MIDI Faders and the DAW Control Surfacefeature was being used and the master fader touched.This has been fixed.ª Change in the date information forProject PropertyThe PROJECT Property shows date information, but inprevious versions this was the date of creation. This hasbeen fixed so that the most recently edited date and timeare shown.ª CF cardsA problem has been fixed that had caused the capacity tobe shown incorrectly for CF cards larger than 1G byte.A problem has been fixed that had caused the status of aCF card to be sometimes detected incorrectly when the CFwas formatted at start-up.A problem has been fixed that had caused the status of aCF card formatted on Windows XP or Mac OS 10.4.3 to bedetected incorrectlyª ProjectCreate projectA problem has been fixed which had sometimes made itimpossible to create a new project after the current projectname was edited.Load projectA problem has been fixed in which the LED indicating theselected control room source was displayed incorrectlywhen a project was loaded.A problem has been fixed in which the cascade connectionstatus sometimes became invalid when loading a projectthat changed the cascade master/slave relationship.ª Version 1.30 Remote controlCh 9-16 screen text display when using Sonar4A problem has been fixed in which the text display for eachmodule was not shown in the channel 9-16 screen whenusing Sonar 4 in the Mackie Control mode.Stereo fader operation using Mackie protocoland another external controllerWhen the Mackie Control External Controller was used inconjunction with another External Controller that used theremote fader bank, moving the master fader would operatethe Mackie Control master fader function even when thefader bank was currently assigned to the other controller.This has been fixed.MMC CHASE commandThe MMC machine control CHASE command is nowsupported.In setups in which P2 protocol is used to control a VTR orother device, and the recorder is the time-code slave, therecorder can be set to MMC control to allow recording onthe recorder.Fig 20: machine_P2mmc.pngDTRS REC function setting in P2A problem has been fixed in which it had been impossibleto set the REC function for track 9 or higher when usingP2 to control DTRS.MX-2424 REC function setting via MMCA problem has been fixed in which the REC function couldnot be set correctly when controlling the MX-2424 via MMC.ª Switching of BUSS PAN Follows ST PANduring automation is now disabledSwitching the BUSS PAN Follows ST PAN on/off whileautomation is operating has now been disabled. If youattempt to switch this while automation is operating, apopup message will appear, and the change will not beaccepted.Popup message:Cannot do thiswhile automatio is running.ª Slave Lock processing when cascadeconnection is cancelledA UI improvement has been made so that when you cancelthe cascade connection, the clock master of the slavedevice is set to Internal. When you attempt to cancel thecascade connection, the following popup message willappear.Popup message: