wc_tx003614gb_FM10.fm157Mobile Generator General Maintenance16.7 Checking and Draining the Containment SystemWhen DailyOverview Certain machines are equipped with a containment system. The containmentsystem protects the environment by collecting fluid leaks (fuel, coolant, or oil)which might otherwise contaminate the soil.NOTICE: It is important to check the containment system daily. A large amount offluid collected in a 24-hour period indicates a significant leak.Requirements ■ Machine stopped and engine is cool to the touch■ Machine is on a level surface■ Plastic cloth and a container of sufficient volume to collect drained fluidNote: Collect, store, and dispose of drained fluid in accordance with currentenvironmental protection regulations.Procedure Perform the procedure below to check and drain the containment system.1. Open an access door on either side of the machine. The containment system(a) surrounds the fuel tank (b).2. Check the fluid level in the containment system.3. If fluid has accumulated, drain the containment system.a. Place a plastic cloth and a collection container beneath the machine.b. Remove the drain plug (c) and gasket. Drain accumulated fluid into a suitablecontainer.c. Inspect the gasket and replace if necessary.d. Re-install the drain plug and gasket.Result The containment system has now been checked and drained.wc_gr009227acb