CHKADJ Periodic checks and adjustments3-13 62Y3A114. Check the thermostat valve opening atthe specified water temperatures.Replace if out of specification.5. Install the thermostat, new gasket, ther-mostat cover, and cover.Checking the cooling water passage1. Check the cooling water inlet cover 1and cooling water inlet for clogs. Clean ifnecessary.2. Place the lower unit in water, and thenstart the engine.3. Check for water flow at the cooling wateroutlet. If there is no water flow, check thecooling water passage inside the out-board.Control system 3Checking the throttle cable operation1. Check that the throttle cam 1 is at thefully closed position a when the remotecontrol lever is in neutral or the throttlegrip is fully closed. Adjust the throttlecable length if necessary as follows.2. Loosen the locknut 2, remove the clip3, and then disconnect the throttle cablejoint 4.Water temperature Valve lift abelow60 °C (140 °F) 0 mm (0 in)above70 °C (158 °F)more than3 mm (0.12 in)S62Y332011S62Y33701