Installation checklist 597Installation checklistWhat this chapter containsThis chapter contains a list for checking the mechanical and electrical installation ofthe drive.Checking the installationCheck the mechanical and electrical installation of the drive before start-up. Gothrough the checklist below together with another person. Read chapter Safety onpage 17 of this manual before you work on the drive.CheckMECHANICAL INSTALLATIONThe ambient operating conditions are within allowed limits. (See Mechanical installation:Checking the installation site on page 33 as well as Technical data: Losses, cooling dataand noise on page 382 and Ambient conditions on page 389.)The drive is fixed properly on an even vertical non-flammable wall. (See Mechanicalinstallation on page 33.)The cooling air will flow freely. (See Mechanical installation: Free space around the driveon page 34.)The motor and the driven equipment are ready for start. (See Planning the electricalinstallation: Checking the compatibility of the motor and drive on page 40 as well asTechnical data: Motor connection data on page 385.)ELECTRICAL INSTALLATION (See Planning the electrical installation on page 39 andElectrical installation on page 49.)For ungrounded and corner-grounded systems: The internal EMC filter is disconnected(EMC screw removed).The capacitors are reformed if the drive has been stored over a year.