Technical SpecificationsX - 214 SCOPIXTechnical SpecificationsMains « Harmonics » Analysis Mode« Recorder » ModeDisplay of "Harmonics" Selection of the page in the "Display" menuEven harmonics 2 to 60 + Fundamental on 2 pagesOdd harmonics 3 to 31 + Fundamental on 2 pagesAll harmonics 2 to 61 + Fundamental on 4 pagesFundamental Frequency of thesignal analyzed 40 to 450 HzMeasurement accuracyLevel of Fundamental ± 2 % ± +10 of ReadingLevel of Harmonics ± 3 % ± +10 of ReadingHarmonic Distortion ± 4 %Oscilloscope not equippedwith theEXTENDED ACQUISITIONMEMORY optionOscilloscope equipped with theEXTENDED ACQUISITIONMEMORY optionRecording period from 2 seconds to 1 monthSampling rate from 800 μs to 17 mins 51 secs from 40 μs to 53.5 secsFault capture 10 faults in memory up to500 faults in files100 faults in memory up to200 faults in filesTriggering Triggering search by sample analysis;Trigger if Detection of:• Signal above threshold• Signal below threshold• Signal below or above threshold• Signal outside of two defined limitsTrigger event period Trigger if the condition is verified during a parameterizable period:Min. value of the period Recording period / 625 Recording period / 12500Max. value of the period Recording period / 4 Recording period / 4Display Search for minimum and maximumFault searchVertical, horizontal accuracy Identical specifications to those in "Oscilloscope" modewww.ShopAEMC.comShop for AEMC products online at: 1.877.766.5412