CHAPTER 4Using the Gateway198Sensor settingsFigure 219. Sensor type - Sensor settings - LC• Logical channel - enter the logical channel of the LC sensor.Conversion settingsFigure 220. Sensor type - Conversion settings - LC• Sensor table - if you want to use a non-linear sensor, selectone of the sensor tables already defined in the menu item“Sensor Tables” for conversion/linearization; if you intend touse a linear sensor, select “none”;•Figure 221. Sensor type - Conversion settings - Sensor table - LCNote: If a sensor table is entered for a non-linear sensor, the fol-lowing entries for Linear input value refer to the output val-ues of the linearization table and not to the voltagemeasured on the analog pin!• Linear input value - entry of the minimum and maximum valueof the range within which the sensor delivers measurements;