12 123 Configuration on the Printer3.1 Configuration Parameters of the Applicator Start menu. Select Setup > Labelling.Parameter Meaning DefaultTransfer mode Setting the operation mode Blow on Blow onCycle sequence Setting the application modePrint-Apply :An external start signal releases the print of a label and following theapplication of the label. After a cycle is complete, the pad without labelwaits in the start position.Apply-Print:An extra signal starts the print of the first label and the transfer of thelabel to the pad. The external start signal releases the application of thelabel and following the print and transfer of the next label.After a cycle is complete, the pad with a label is in the waiting position.Print-ApplyWaiting position Only for mode = Blow on and Cycle sequence = Apply-Printup: Pad waits in the start position for the start signaldown: Pad waits in the labelling position for the start signalupBlow time Controls how long the pads with the suction plates are pressed together. 200 msSupport delay on Setting the switch-on delay (max. 2,5 s) for the supporting air betweenprint start and switching on the supporting air. The delay preventsswirling at the front of the label and, consequently, avoids faults whenthe label is being picked up from the printer.0 msSupport delay off Setting the switch-off delay (max. 2,5 s) for the supporting air betweenthe end of label forwarding and switching on the supporting air. Thedelay can be useful to separate the rear edge of the label from thecarrier to avoid errors and to improve the accuracy of label positioning270 msStart delay Delay (max. 2,5 s) between start signal and the start of an labellingcycle.Allows e.g. the use of product sensors at conveyors.0 msLock time Controls the time from the start of flag formation until the pliers open 250 msVacuum delay On - The vacuum will be switched on after the label feed is completed.Off - The vacuum will be switched on when the label feed starts.OffVacuum control Setting the label transfer check from printer to pad and from pad toproduct by the vacuum sensorOnLabel hand-over Passive - The pad waits in front of the dispense edge for the label.Active - The pad moves to the dispense edge and takes the label.PassiveCleaning blow Activation of a short blow impulse after the application of the label toclean the suction channels.OnPeel-off position Shift the position of the dispensed label relative to the dispensing edge.The setting can also be adjusted by the software.The settings of configuration and software are added together.0.0 mmTable 2 Parameters of the Setup > Labelling menu