52 5210 Test Reporttarget target actual unitSerial No. PCB apllicator control 575194352728controller/index-PCB apllicator control 5979208/031. adjustments1.1 adjustment compressed air = 4.50 OK bar1.2 pressure cyl. 2 = 2.00 2.00 bar1.3 vacuum sensor checked, vacuum value topped <= -0.65 -0.68 bar1.4 vacuum throttle valve = -0.60 OK bar1.5 adjust OK1.6 function with adjusted blow tube OK1.7 sensor compressed air checked OK1.8 function sensor labeling position OK1.9 Function sensor start position main cylinder OK1.10 position sensor (PLIO 1) = 8.00 8.00 mm1.11 position sensor (PLIO 2) = 0.00 0.00 mm1.12 position sensor (PLIO 3) = 8.00 8.00 mm1.13 position sensor (PLIO 4) = 8.00 8.00 mm1.14 position sensor (PLIO 5) = 12.00 12.00 mm1.15 position sensor (PLIO 6) = 17.00 17.00 mm1.16 valve opening 1.01 turns anticlockwise = 9.00 9.001.17 valve opening 1.02 turns anticlockwise = 8.00 8.001.18 valve opening 2.04 turns anticlockwise = 8.00 8.001.19 valve opening 2.03 turns anticlockwise = 9.00 9.001.20 valve opening 3.05 turns anticlockwise = 7.00 7.001.21 valve opening 3.03 turns anticlockwise = 3.00 3.001.22 valve opening 3.06 turns anticlockwise = 8.50 8.501.23 Function sensor start position StartPosZ/EndPosZ OK1.24 adjustment aperture-claw = 20.00 20.00 mm1.25 number of cylce per minute 16.00 18.00 18.002. functional checks2.1 part-no./size test-label 80x252.2 no collision of the tubes OK2.3 notes: ---2.4 notes: ---2.5 labeling without malfunction OK3. final assembly3.1 visual check OK3.2 fix OK3.3 apply product-, warn labels OK4. packing4.1 by pack complete (check scope of delivery), package labelled OK4.2 unit cleaned and boxed OK4.3 date: Index: (0) 20.03.2020Fig. 56 Test report example applicator 4712Description in the test report Description in the im Document/Pneumatic drawingCylinder 1 Cylinder (1) ZCylinder 2 Cylinder (2) FlagCylinder 3.0 Cylinder (3.0) Peel PositionCylinder 3.1 Cylinder (3.1) Pliers