34 346.14 Set Cylinder Flag / Actor 26.14.1 Set Cylinder 'flag' throttle valves2.032.04ZX YThrottle valve (2.04) movement insideMarker on the tube with the number 3Close the throttle valve (2.04) completely.Turn the set screw clockwise until it stops.If no different value is noted in the test report,open the throttle valve (1.01) by turning it 8 turns counterclockwise.Throttle valve (2.03) movement outsideMarker on the tube with the number 4Close the throttle valve (2.03) completely.Turn the set screw clockwise until it stops.If no different value is noted in the test report,open the throttle valve (2.03) by turning it 9 turns counterclockwise.Fig. 36 Cylinder 'flag' throttle valves6.14.2 Set Cylinder 'flag' sensors12.018 mm8 mm32.01Sensor (2.01) Pads in start positionMarker on the sensor with the number 3If no different value is noted in the test report,set the distance between the edge of the sensor (2.01) and theedge of the connection ring (1) to 8 mm.As a check, switch on the printer and switch on compressed air.In the start position of the applicator, the LED on the sensor mustlight up. The lifting cylinder is completely retracted in this position.Sensor (2.02) Pads are closedMarker on the sensor with the number 4If no different value is noted in the test report,set the distance between the edge of the sensor (2.02) and theedge of the connection ring (3) to 8 mm.As a check, switch on the printer and the LED on the sensor doesnot light up. The LED lights up when the pair of pads is closed.Fig. 37 Cylinder 'flag' sensors6 Adjustments