Es-1xe GroupFast Network 10 MIB Reference GuidePage 6-45Step 3. If the GetResponse did not indicate an error, then wait for (andacknowledge) the enterprise specific trap that contains thesxlpbkOperation parameter. [Multiple traps may be sent if there aremultiple errors.]A port’s loopback operation is automatically terminated after the requisitenumber of packets have been sent. To immediately terminate a port’s loopbackoperation, the NMS may perform the following stepsStep 1. Issue a SetRequest PDU, specifying the value loopback-off forsxlpbkOperation.Step 2. Wait for the GetResponse PDU. If the port was in local loopback, thenthe port will be automatically re-enabled to the extent specified by thecurrent value of sxsprotoEntry for that port.sxlpbkTable {sxlpbk 1}Not-AccessibleA list of interface entries; one per port.sxlpbksxlpbkEntry {sxlpbkTable 1}Not-AccessibleA set of objects for an interface entry. The individual components are describedbelow.sxlpbkIndex {sxlpbkEntry 1}Integer Read-OnlyThe port number, beginning with 1 for the first port.sxlpbkOperation {sxlpbkEntry 2}Integer Read-WriteThe type of loopback being performed. Setting sxlpbkOperation to loopback-offcauses loop back operation to terminate. Setting sxlpbkOperation toloopback-local or loopback-remote causes loopback operation to commence, andthe FN10 automatically resets sxlpbkOperation to loopback-off when theloopback operation has completed. Possible values• loopback-off (1) – terminate loopback• loopback-local (2) – commence local loopback• loopback-remote(3) – commence remote loopback