COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR105 REV.0 JULY 2001CHAPTER 2 NEW FUNCTIONS2-906.6.1 Manual Feed Tray Assemblya. Removing the Manual Feed Tray Unit1) Remove the control panel unit. (See8.4.2.a.)2) Remove the upper right cover.3) Open the manual feed tray unit [1].4) Remove the screw [2], and detach thedoor tape [3] from the machine side.5) Remove the screw [4], and detach theconnector cover [5].6) Disconnect the connector [6], and de-tach the manual feed tray unit [1] up-ward while it is kept open at about 90°.F02-606-01b. Fitting the Side Guide Timing Belt for the Manual Feed Tray Assembly1) Butt the rack plate [1] of the manualfeed tray against section A (in openstate).2) Move the slide volume [2] in the direc-tion of B, and fit the timing belt [3] tothe pulley [4] and the pulley [5].F02-606-02[1][6][5][4][2] [3][4] [5][3][1] A[2]B