COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001CHAPTER 6 FIXING SYSTEM6-10 PE000The main thermistor (TH1) has poor contact or an open circuit. The thermalswitch (TP1) has an open circuit. The main /sub heater has an open circuit.The main power supply PCB is faulty. The DC control PCB is faulty. Thedoor switch is faulty.E001The main thermistor (TH1) has a short circuit. The sub thermistor (TH2)has a short circuit. The main power supply PCB is faulty. The DC controllerPCB is faulty?E002The main thermistor (TH1) has poor contact or an open circuit. The thermalswitch has an open circuit (TP1). The fixing heater has an open circuit. TheAC driver PCB is faulty. The DC controller PCB is faulty. The door switchis faulty.E003The main thermistor (TH1) has poor contact or an open circuit. The thermalswitch has an open circuit (TP1). The fixing heater has an open circuit. Themain power supply PCB is faulty. The DC controller PCB is faulty. Thedoor switch is faulty.E007The fixing motor (M4) is faulty. The fixing film sensor (P26) is faulty.If a code from E000 through E003 is indicated, the indication will not bereset even when the main power switch is turned off and then on, requiringclearing of the error in service mode(COPIER>FUNCTION>CLEAR>ERR).If E001 or E003 is detected within 3sec after the front cover switch is iden-tified as being open/closed, however, the error indication will be reset whenthe main power switch is turned off and then on. This is to prevent the userfrom placing a service call in response to an error detected while the switchoperation is not stable (as occurring immediately after the switch is turnedon/off).