COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001CHAPTER 6 SELF DIAGNOSIS6-45 TE5800000 The delivery tray upper limit sensor (S13) goes ON while the delivery trayascent/descent motor (M5) is in operation.The clock signal of the delivery tray ascent/descent motor clock sensor (S9)is not detected 15 times or more within 0.8 sec while the delivery tray as-cent/descent motor (M5) is in operation.The delivery tray paper height sensor (S10) does not go ON 4 sec after thedelivery tray ascent/descent motor (M5) starts to move up.The delivery tray paper height sensor (S10) does not go OFF 4 sec after thedelivery tray ascent/descent motor (M5) starts to move down.Cause The delivery tray ascent/descent motor (M5) is faulty. The delivery tray pa-per height sensor (S10) is faulty, the harness is disconnected, or an opencircuit exits. The delivery tray ascent/descent motor lock sensor (S9) isfaulty, the connector is disconnected, or an open circuit exits. The deliverytray ascent/descent motor is subjected to an excess load. The finisher con-troller PCB is faulty.E5850000 At the start of the motor CCW operation, the stack handling motor (M2)may be driven for a specific number of rotations; however, the stack deliv-ery lever home position sensor (S8) does not go ON.Cause The stack handling motor (M2) is faulty. The stack delivery lever home po-sition sensor (S8) is faulty, the connector is disconnected, or an open circuitexits. The stack handling motor (M2) relay harness is faulty. The returnroller is faulty.