Interfaces | 415Figure 19-34. Setting Auto-Negotiation OptionsFor details on the speed, duplex, and negotiation auto commands, see the Interfaces chapter of the FTOSCommand Reference Guide.Adjust the keepalive timerUse the keepalive command to change the time interval between keepalive messages on the interfaces.The interface sends keepalive messages to itself to test network connectivity on the interface.To change the default time interval between keepalive messages, use the following command:To view the new setting, use the show config command in the INTERFACE mode.View Advanced Interface InformationDisplay Only Configured InterfacesThe following options have been implemented for show [ip | running-config] interfaces commands for (only)linecard interfaces. When the configured keyword is used, only interfaces that have non-defaultconfigurations are displayed. Dummy linecard interfaces (created with the linecard command) are treatedlike any other physical interface.Figure 19-35 lists the possible show commands that have the configured keyword available:Command Syntax Command Mode Purposekeepalive [seconds] INTERFACE Change the default interval between keepalivemessages.FTOS(conf)# int gi 0/0FTOS(conf-if)#neg autoFTOS(conf-if-autoneg)# ?end Exit from configuration modeexit Exit from autoneg configuration modemode Specify autoneg modeno Negate a command or set its defaultsshow Show autoneg configuration informationFTOS(conf-if-autoneg)#mode ?forced-master Force port to master modeforced-slave Force port to slave modeFTOS(conf-if-autoneg)#