692 | Port Monitoringw w w . d e l l . c o m | s u p p o r t . d e l l . c o m • The C-Series and S-Series may only have four destination ports per port-pipe. There is no limitation onthe total number of monitoring sessions.Table 32-1 lists the maximum number of monitoring sessions per system. For the C-Series and S-Series,the total number of sessions is derived by consuming a unique destination port in each session, in eachport-pipe.Port Monitoring on E-SeriesBoth the E-Series TeraScale and E-Series ExaScale support the following.• FTOS supports one destination (MG) port per monitoring session. The same destination port (MG) canbe used in another monitoring session.• One destination (MG) port can monitor up to 28 source (MD) ports.• A port cannot be defined as both a source (MD) and a destination (MG) port (Message 1).E-Series TeraScaleThe E-Series TeraScale system supports 1 monitoring session per port-pipe. E-Series TeraScale supports amaximum of 28 port pipes.Table 32-1. Maximum Number of Monitoring Sessions per SystemSystem Maximum Sessions System Maximum SessionsC150 ∞ (Note) E1200/E1200i (TeraScale) 28C300 ∞ (Note) E1200i (ExaScale) ∞S50V, S50N ∞ (Note) E600/E600i (TeraScale) 14S25P ∞ (Note) E600i (ExaScale) ∞E300 6Note: On the C-Series and S-Series, there is no limit to the number of monitoring sessions per system,provided that there are only 4 destination ports per port-pipe. If each monitoring session has a uniquedestination port, then the maximum number of session is 4 per port-pipe.Message 1 Cannot define source (MD) and destination (MG) on same port% Error: MD port is already being monitored.